Structure and Movement(ODP)

1. Arc-extinguish Device It is designed as a structure that can disperse, cool the arc between contacts to be extinguished efficiently when breaking a large current instantly generated by arc grid arranged in parallel.
2. Full Electronic (ODP) Structure It is designed as a structure that can disperse, cool the arc between contacts to be extinguished efficiently
3. Checking the movement by handle
- Trip display
Incase of auto-breaking due to accidental current such as overcurrent, short-circuit current, handle is stopped at the position in the middle of between ON and OFF.
- Reset operation
In case of Trip due to accidental current, remove the cause of accident and reset the handle to OFF by hand and then to ON for normal operation.
|
 |
4. Improved quality with the durability of product by using special materials
Structure and Movement (Thermal Magnetic)

1. Arc-extinguishing Device It is designed as a structure that can disperse, cool the arc between contacts to be extinguished efficiently when breaking a large current instantly generrated by arc grid arranged in parallel. |
 |
2. Current Limiting Structure Newly developed current limiting structure sharply decreases and cuts off arc energy without fail.
3. Simultaneous Trip Structure There is no fear of single-phase running of three-phase motor because three-phase is cut off simultaneously even though electric current flows on any one phase.
A list of types of Molded Case Circuit Breakers(Series for Panel board)
|
Frame Size
|
30AF
|
50AF
|
|
Type
|
for Panel board
|
for Panel board
|
|
Type name
|
TDB-32
|
TDB-32a
|
TDB-32ah
|
TCB-32bh
|
TCB-52
|
TCB-53
|
|
External appearance
|
|
|
|
|
|
|
Rated current(A)
|
15,20,30
|
3,5,10,15,20,30,40,50
|
|
Rated voltage(Ue) AC(V)
|
220
|
220
|
300
|
220
|
460
|
|
Number of poles, Number of elements
|
2P2E
|
2P2E
|
2P2E
|
2P2E
|
3P3E
|
|
Protective function
|
Overload and short-circuit protection
|
|
Rated breaking capacity (kA)
|
(sym) AC460V
|
-
|
-
|
-
|
-
|
2.5
|
|
(sym) AC380V
|
-
|
-
|
-
|
-
|
2.5
|
|
AC220V
|
1.5
|
1.5
|
2.5
|
5
|
5
|
5
|
Dim 
|
a
|
32
|
33
|
35
|
50
|
75
|
|
b
|
70
|
70
|
82.5
|
96
|
96
|
|
c
|
36.8
|
42
|
60
|
60
|
60
|
|
d
|
55
|
56.5
|
78
|
81
|
81
|
|
Product weight(kg)
|
0.09
|
0.1
|
0.48
|
0.3
|
0.4
|
|
Overcurrent trip type
|
Thermal magnetic
|
ODP
|
|
Insulating barrier basic (Power side)
|
-
|
-
|
-
|
-
|
|
Installation method
|
Screw
|
|
Acquired standards
|
Electrical Appliances Safety Certification
|
O
|
O
|
O
|
O
|
|
KSC8321
|
O
|
O
|
O
|
O
|
A List of Types of Molded Case Circuit Breakers(Economic Series)
|
Frame Size
|
30AF
|
50AF
|
|
Type
|
for Panel board
|
for Panel board
|
|
Type name
|
TEB-52
|
TEB-53
|
TEB-54
|
TEB-52
|
TEB-53
|
TEB-54
|
|
External appearance
|
|
|
|
|
|
|
|
Rated current(A)
|
3,5,10,15,20,30,40,50
|
30,40,50
|
|
Rated voltage(Ue) AC(V)
|
460
|
460
|
460
|
460
|
460
|
460
|
|
Number of poles, Number of elements
|
2P2E
|
3P3E
|
4P3E
|
2P2E
|
3P3E
|
4P3E
|
|
Protective function
|
Overload and short-circuit protection
|
|
Rated breaking capacity (kA)
|
(sym) AC220V
|
-
|
5
|
5
|
10
|
10
|
10
|
|
(sym) AC380V
|
-
|
5
|
5
|
10
|
10
|
10
|
|
AC220V
|
10
|
10
|
10
|
22
|
22
|
22
|
Dim 
|
a
|
50
|
75
|
100
|
50
|
75
|
100
|
|
b
|
130
|
130
|
130
|
130
|
130
|
130
|
|
c
|
60
|
60
|
60
|
60
|
60
|
60
|
|
d
|
80
|
80
|
80
|
80
|
80
|
80
|
|
Product weight(kg)
|
0.45
|
0.65
|
0.8
|
0.45
|
0.65
|
0.8
|
|
Overcurrent trip type
|
ODP
|
|
Insulating barrier basic (Power side)
|
O
|
O
|
O
|
O
|
O
|
O
|
|
Installation method
|
Screw
|
|
Acquired standards
|
Electrical Appliances Safety Certification
|
O
|
O
|
O
|
O
|
O
|
O
|
|
KSC8321
|
O
|
O
|
O
|
O
|
O
|
O
|
|